A/B Series

Range

  • › Airflow over 80'000 m³/h.

  • › High efficiency, up to 80%

  • › Low pressure drops; suggested ΔP 200 Pa.

  • › Max differential pressure up to 2000 Pa (extra option up to 2500 Pa)

  • › Max working temperature up to 90°C (no silicone). Option up to 200°C.

Download pdf

Material characteristics

Aluminium (AL)

Aluminium is used in most of the applications. This is thanks to its characteristics regarding corrosion resistance, ease of processing, non-flammability and reliability over the time.

Aluminium with epoxy protection (AC)

In enviroments with aggressive atmosphere, usually is recommended that aluminium is protected by a paint coating non-toxic based epoxy corrosion resistant (AC version - GOLD).

B·Blue (AB)

To reduce the consumption of electricity for cooling, it's possible to integrate a plate heat exchanger in an indirect evaporative cooling system. Recuperator has developed a new hydrophilic aluminium coating that improves system efficiency and ensures high corrosion resistance.

Dimensions

Typology Model B1xB1 E1 A1 Fins spacing
03 - 04 - 05 - 06 300 - 400 - 500 - 600 424 - 566 - 707 - 849 1300 1.50 to 9.50
75 - 08 - 85 - 09 - 10 - 12 755 - 805 - 855 - 905 - 1005 - 1205 1068 - 1139 - 1209 - 1280 - 1421 - 1705 2500 2.40 to 9.50
15 - 16 - 17 - 18 - 20 - 24 1510 - 1610 - 1710 - 1810 - 2010 - 2410 2135 - 2277 - 2418 - 2560 - 2843 - 3409 2500 3.10 to 9.50

Measurements in mm.
Maximum lengths can be divided into several modules according to steps and weights.

Options

Default

Available

Unvailable

Default

Available

Unvailable

F Series A/B Series E Series X Series
F Series A/B Series E Series X Series

AZ

Hips reduced by 1 mm

Aluminum side plates, made with reduced thickness, with smooth top and easy installation (slide-in), combined with CD option. This solution (prerogative of some models of the B series) allows to have a greater finned surface, which can be important in small spaces. These devices are also very light and easy to handle.

PROFILES

CD

Special profile (combined with AZ and AR)

It is possible to combine special head covers so that they can be quickly installed in the air handling units (slide-in).

SEALING

NS

Silicon free

Recuperator devices are produced without the use of silicone. However, in some applications (for example, for high temperatures), in order to guarantee the sealing between air flows, it is necessary to use this sealant.

SC

Additional sealing

Option that guarantees a greater seal between the two air flows. This option is recommended in particular applications such as hospitals, clean rooms, spray booths etc.

SM

Mechanical sealing

Standard option produced during the stamping phase only for the F series.

BY-PASS
PDF

BS

Side bypass without damper

Option that provides a side by-pass section without damper.

BZ

Bypass centrale senza serranda

Option that provides a central by-pass section without damper.

BYPASS AND DAMPER
PDF

BP

Lateral bypass with external control damper

Option that includes a lateral by-pass section equipped with a damper with external control.

VP

Lateral bypass with painted damper external control

Option that includes a side by-pass section equipped with a painted damper with external control.

BD

Lateral bypass with internal control damper

Option that provides a side by-pass section equipped with damper with internal control.

BC

Central bypass with external control damper

Option that includes a central by-pass section equipped with a damper with external control.

BE

Central bypass with internal control damper

Option that includes a central by-pass section equipped with a damper with internal control.

FD

Lateral bypass with damper without plastic parts and internal control

Option that includes a side by-pass section equipped with a damper without plastic parts and with internal control.

XS

High differential pressure

Reinforced plate for 3000Pa / 12inwc of pressure. Available only for F series model

TV

Epoxy protection

Epoxy protection for both corner profile and side plates against aggressive environments. Max temperature allowed 90°C. This option is usually associated with AC or AB fins.

AR

Side plate

Side plate with fold and with smooth top and easy installation (slide-in). Lower limits than AE side plates.

AF

Selected Side plates

Side plates, in case of limited space, can be selected (same construction with smaller dimensions). Compared to the AE, AF has lower limits for heat exchanger in one piece. Always 20mm (0.78in) of thickness